• Applications
SBEM
  • Home
  • Overview
  • Products
  • Industries
    • Water Treatment Plant
    • Waste Water Management
    • Food and Beverage
    • Power Plants
    • Cement
    • Irrigation
    • Steel
    • Steam Plant
    • Oil and Gas – Upstream
    • Oil and Gas – Downstream
  • Contact Us
SBEM
Keep Empty
  • Level
    • Level Transmitters
      • Radar
        • ProWave80G Radar 138 W81
        • ProWave80G Radar 138 W83
        • ProWave80G Radar 138 W84
        • ProWave80G Radar 138 W85
        • AquaWave 138 WB
        • AquaWave 138 W51
        • AquaWave 138 W52
      • Ultrasonic 136 series
        • 136 ULT Ultrasonic Level Transmitter
        • 136 ULP Display
        • 136 ULR
      • Hydrostatic
        • 103 HPT
        • 171 HLT
      • Magnetostrictive
        • 134-DLi
      • Capacitive
        • 103 CLT – Non-Conductive
        • 103 CLT – Conductive
        • 104 Loss of Head
      • Float & Tape
        • 131 T
    • Level Switches
      • Mechanical
        • Side Mounted Float 137 EAEY
        • Side Mounted Pneumatic Control 137 PNP
        • Paddle Type 135 LC
        • Top Mounted Displacer 137 D
      • Electronic
        • Conductiviy 130 RC
        • Conductiviy 130 IC
        • LIQUIDS 114 MLS
    • Tank Gauging
      • ATLG
        • 133 ATLG Automatic tank level gauge
        • 133 STDT Smart Tank Data Tx
        • 133 TS 2-wire Tx with Limit Switch
        • 133 LS
      • Servo
        • 139 M series Servo gauge
        • TS/TSIC
        • 133 CIU Communication Interface Unit
        • RCU
        • 133 TMP Average Temperature Sensor
        • PPU
        • Calibration Chamber
      • Magnetostrictive
        • 134 DLI
      • Hydrostatic
        • 103 HPT
        • 103 HTL
  • Flow
    • Electromangetic Flow Meters
      • 151 MFM P - Prime
      • 151 MFM E - Eco
      • 151 MFM W - Water
      • 151 MFM B – Battery operated
    • Ultrasonic Flow Meter
      • Parasonic Insertion
        • 153 UTW
      • Parasonic Bulk
        • 153 UIF
      • Parasonic ClampOn
        • 153 UCW
        • 153 UCH
        • 153 UCM
      • Parasonic Multi Path
        • 153-MUF Multipath Ultrasonic Flowmeter
    • Residential Metering
      • AquaSonic 153 RWM
      • AquaLink
    • Open Channel Flow
      • Ultrasonic - 136 ROF
      • Capacitance - 104 ROF
  • Pressure
    • 171 PT Pressure Transmitter
    • 171 SPT Smart Pressure Transmitter
    • 171 IPT Intelligent Pressure Transmitter
    • 171 DPT Differential Pressure Transmitter
    • 171 BPT Battery Operated Pressure Transmitter
  • Energy
    • 151 BTU Electromagnetic Energy Meter
  • IoT
    • 151 MFM - B
    • 138 WB
    • 171 BPT
    • AquaSonic 153 RWM
    • 153 UIF
    • SenSphere Web Application
    • SensLink Mobile Application
  • Accessiores
    • Displays
      • 176 Remote Indicator
      • 176 LPI Loop Power Indicator
      • 103 HTL Tank Level Indicator
      • 191 Totalizer Indicator
    • RTU
      • 200-SB410M
Open Menu
  • Home
  • Overview
  • Products
    • Level Measurement
      • Level Transmitters
        • Radar
          • ProWave80G Radar 138 W81
          • ProWave80G Radar 138 W83
          • ProWave80G Radar 138 W84
          • ProWave80G Radar 138 W85
          • AquaWave 138 WB
          • AquaWave 138 W51
          • AquaWave 138 W52
        • Ultrasonic Technology
          • 136 ULT Ultrasonic Level Transmitter
          • 136 ULP Display
          • 136 ULR
        • Hydrostatic Technology
          • 103 HPT
          • 171 HLT
        • Magnetostrictive
          • 134-DLi
        • Capacitive
          • 103 CLT Conductive
          • 103 CLT Non Conductive
          • 104 Loss of Head
        • Float & Tape
          • 131 T
      • Level Switches
        • Mechanical
          • Side Mounted Float 137 EA
          • Top Mounted Displacer 137 D
          • Side Mounted Pneumatic Control 137 PNP
          • Paddle Type 135 LC
        • Electronic
          • Conductiviy 130 RC
          • Conductiviy 130 IC
          • LIQUIDS 114 MLS
          • Solids 114 MLS
      • Tank Gauging
        • ATLG
          • 133 ATLG Automatic tank level gauge
          • 133 STDT Smart Tank Data Tx
          • 133 TWT
          • 133 LS 2-wire Tx with Limit Switch
        • Servo
          • 139 M series Servo gauge
          • TS/TSIC
          • 133 CIU Communication Interface Unit
          • RCU
          • 133 TMP Average Temperature Sensor
          • PPU
          • Calibration Chamber
        • Magnetostrictive
          • 134 DLi
        • Hydrostatic
          • 103 HPT
          • 171 HTL
    • Flow Measurement
      • Electromangetic Flow Meters
        • 151 MFM P - Prime
        • 151 MFM E - Eco
        • 151 MFM W - Water
        • 151 MFM B – Battery operated
      • Ultrasonic Flow Meter
        • Parasonic Insertion
          • 153 UTW
        • Parasonic Bulk
          • 153 UIF
        • Parasonic ClampOn
          • 153 UCW
          • 153 UCH
          • 153 UCM
        • Parasonic Multi Path
          • 153-MUF Multipath Ultrasonic Flowmeter
      • Residential Metering
        • AquaSonic 153 RWM
        • AquaLink
      • Open Channel Flow
        • Ultrasonic - 136 ROF
        • Capacitance - 104 ROF
    • Pressure Measurement
      • 171 PT Pressure Transmitter
      • 171 SPT Smart Pressure Transmitter
      • 171 IPT Intelligent Pressure Transmitter
      • 171 DPT Differential Pressure Transmitter
      • 171 BPT Battery Operated Pressure Transmitter
    • Energy
      • 151 BTU
    • IoT
      • 151 MFM – B
      • 138 WB
      • 171 BPT
      • AquaSonic 153 RWM
      • 153 UIF
      • SenSphere Web Application
      • SensLink Mobile Application
    • Accessiores
      • Displays
        • 176 Remote Indicator
        • 176 LPI Loop Power Indicator
        • 103 HTL Tank Level Indicator
        • 191 Totalizer Indicator
      • RTU
        • 200-SB410M
  • Industries
    • Water Treatment Plant
    • Waste Water Management
    • Food and Beverage
    • Power Plants
    • Cement
    • Irrigation
    • Steel
    • Steam Plant
    • Oil and Gas – Upstream
    • Oil and Gas – Downstream
  • Applications
    • Flow Measurement of Water in Utility Water System at Power Plant
    • Flow Measurement in Irrigation Water Lines Using Ultrasonic Flow Meter
    • Residential Water Consumption Monitoring Using 153 RWM
    • Flow Measurement on WTP Inlet Line for Accurate Raw Water Monitoring
    • Differential Level Measurement in Bar Screening Channels
  • Contact Us
  • Home
  • Products
  • Flow
  • Electromagnetic Flow Meter
  • 151 MFM – B

151 MFM – B

A battery-operated electromagnetic flow meter is a versatile, maintenance-free instrument used for measuring the flow of conductive liquids without external power. Utilizing Faraday’s Law of Electromagnetic Induction, it generates a magnetic field and measures the voltage induced by the fluid’s flow, ensuring accurate, obstruction-free measurement. Powered by long-life lithium batteries, it is ideal for remote or mobile installations. Key specifications include accuracy of ±0.5%, conductivity of measured liquid is ≥50µS/cm, IP68 protection, and data logging via GSM / GPRS. Typical applications include water distribution, irrigation systems, and wastewater management.

360° Product View
  • Features
    • Wieless Communication: IoT-enabled
    • Recommended for Remote Locations
    • Bidirectional flow measurement
    • GSM / GPRS Connectivity
    • Remote sensor suitable for submerged / buried applications
  • Specification
    Specification Details
    Sensor Size DN 15 to DN 1000
    Accuracy 1 ±0.5% of Measured Flow
    Repeatability ±0.2% (At Constant Flow)
    Measuring Range Up to 15 m/s
    Conductivity of Measured Liquid ≥50 µS/cm
    Power Supply 3.6V Battery Pack (Replaceable)
    Battery Life Up to 5 Years
    Mounting Version Integral or Remote
    Displayed Units Totalised Flow: m³, L
    Instantaneous Flow: m³/hr, m³/min, m³/sec, L/hr, L/min, L/sec
    Display Graphical LCD with Backlight
    4-20mA Current Output Not Available
    Digital Outputs Optional: 1 No. Open Collector Status Output / Pulse Output, 50Hz max. (Configurable)
    In-built Data Logger Available (On Request)
    Communication Interface Optional: RS485 / GSM / GPRS – MQTT / TCP-IP / UDP
    Communication Protocol GPRS – MQTT / TCP-IP / UDP
    Sensor Housing Material Standard: CS, Optional: SS316 / SS304
    End Connection ANSI / DIN / AWWA
    Measuring Tube Material SS304, SS316
    Electrode Material SS316 / SS316L / Hastelloy C / Titanium
    Protection Class Sensor: Weatherproof: IP67 (Standard) or IP68 (Optional)
    Converter: For Remote Version: IP67 & For Integral Version: IP67
    Cable Length 2 For Remote Version: 10 m Standard / Additional Meters on Request
  • Application
    • Smart City Water Management
    • Smart Water Network – DMA
    • Water & Wastewater Management
    • Municipal Water Supply System
    • Irrigation and Agricultural
    • Flood Monitoring System
    • Food & Beverage System
  • Downloads
    Leaflets:
    • 151 MFM - B Download

Download Leaflet

    Contact

    • +91-7720065260 | +91-8600042374
    • marketing@sbem.co.in
    • Gat No. 326, Shriramnagar, Gaud Dara Road, Khedshivapur, Pune - 412205.
    Follow Us

    Media

    • News
    • Blogs
    • Gallery

    Careers

    • Life @SBEM
    • Job Opportunities

    We Care

    • Sustainability
    • Safety
    • Social Responsibility

    Support

    • Downloads Leaflets & Brochures
    • Where To Buy
    • FAQs
    © 2026 Copyright SBEM Pvt. Ltd.