| Power Supply | Std. -85-230VAC; Optional -24VDC |
| Measured Values | Volumetric Flow, Flow Velocity, Flow Direction, Speed of Sound, Quality of measured signal |
| Flow Velocity | 0-32m/s bi-directional |
| Accuracy | ±1%*for dia. Ø50mm and v>0.5m/s |
| Repeatability | 0.3% |
| Sensors | Clamp-on and insertion (For insertion type sensors, refer LF-153-0804) |
| Display | 2Line backlight LCD |
| Keyboard | 4X4 Numeric Keyboard membrane |
| Pipe Materials | Mild Steel/Carbon Steel, Stainless Steel, Cast Iron, Ductile Iron, PVC, Plastic* |
| Lining | Mortar, Tar Epoxy, Rubber |
| Outputs | 4-20mA/0-20mA; Relay output; Open Collector Frequency / Pulse output |
| Communication | RS485 /RS232 with MODBUS (ASCII or RTU) |
| Inputs | Up to 3 Analog input channel sand Up to 2 channel 3Wire compensated Pt100 |
| Data Logging | Built-in or optional PC based |
| Data logging Memory | 2GB (Standard) ,8GB & 16GB (Optional) |
| Protection | IP67(Applicable for Converter & Clamp on Sensors both) |