SBEM
  • Home
  • Overview
  • Products
  • Industries
    • Water Treatment Plant
    • Waste Water Management
    • Food and Beverage
    • Power Plants
    • Cement
    • Irrigation
    • Steel
    • Steam Plant
    • Oil and Gas – Upstream
    • Oil and Gas – Downstream
  • Contact Us
SBEM
Keep Empty
  • Level
    • Level Transmitters
      • Radar
        • ProWave80G Radar 138 W81
        • ProWave80G Radar 138 W83
        • ProWave80G Radar 138 W84
        • ProWave80G Radar 138 W85
        • AquaWave 138 WB
        • AquaWave 138 W51
        • AquaWave 138 W52
      • Ultrasonic 136 series
        • 136 ULT Ultrasonic Level Transmitter
        • 136 ULP Display
      • Hydrostatic
        • 103 HPT
        • 171 HLT
      • Magnetostrictive
        • 134-DLi
      • Capacitive
        • 103 CLT – Non-Conductive
        • 103 CLT – Conductive
        • 104 Loss of Head
      • Float & Tape
        • 131 T
    • Level Switches
      • Mechanical
        • Side Mounted Float 137 EAEY
        • Side Mounted Pneumatic Control 137 PNP
        • Paddle Type 135 LC
        • Top Mounted Displacer 137 D
      • Electronic
        • Conductiviy 130 RC
        • Conductiviy 130 IC
        • LIQUIDS 114 MLS
    • Tank Gauging
      • ATLG
        • 133 ATLG Automatic tank level gauge
        • 133 STDT Smart Tank Data Tx
        • 133 TS 2-wire Tx with Limit Switch
        • 133 LS
      • Servo
        • 139 M series Servo gauge
        • TS/TSIC
        • 133 CIU Communication Interface Unit
        • RCU
        • 133 TMP Average Temperature Sensor
        • PPU
        • Calibration Chamber
      • Magnetostrictive
        • 134 DLI
      • Hydrostatic
        • 103 HPT
        • 103 HTL
  • Flow
    • Electromangetic Flow Meters
      • 151 MFM P - Process
      • 151 MFM E - Enhanced
      • 151 MFM W - Water
      • 151 MFM B – Battery operated
      • 151 MFM I – Insertion
    • Ultrasonic Flow Meter
      • Parasonic Insertion
        • 153 UTW
      • Parasonic Bulk
        • 153 UIF
      • Parasonic ClampOn
        • 153 UCW
        • 153 UCH
        • 153 UCM
      • Parasonic Multi Path
        • 153-MUF Multipath Ultrasonic Flowmeter
    • Residential Metering
      • AquaSonic 153 RWM
      • AquaLink
    • Open Channel Flow
      • Ultrasonic - 136 ROF
      • Capacitance - 104 ROF
  • Pressure
    • 171 PT Pressure Transmitter
    • 171 SPT Smart Pressure Transmitter
    • 171 IPT Intelligent Pressure Transmitter
    • 171 DPT Differential Pressure Transmitter
    • 171 BPT Battery Operated Pressure Transmitter
  • IOT
    • 151 MFM - B
    • 138 WB
    • 171 BPT
    • AquaSonic 153 RWM
    • 153 UIF
    • SenSphere Web Application
    • SenSync Mobile Application
  • Accessiores
    • Displays
      • 176 Remote Indicator
      • 176 LPI Loop Power Indicator
      • 103 HTL Tank Level Indicator
      • 191 Totalizer Indicator
    • RTU
      • 200-SB410M
Open Menu
  • Home
  • Overview
  • Products
    • Level Measurement
      • Level Transmitters
        • Radar
          • ProWave80G Radar 138 W81
          • ProWave80G Radar 138 W83
          • ProWave80G Radar 138 W84
          • ProWave80G Radar 138 W85
          • AquaWave 138 WB
          • AquaWave 138 W51
          • AquaWave 138 W52
        • Ultrasonic Technology
          • 136 ULT Ultrasonic Level Transmitter
          • 136 ULP Display
        • Hydrostatic Technology
          • 103 HPT
          • 171 HLT
        • Magnetostrictive
          • 134-DLi
        • Capacitive
          • 103 CLT Conductive
          • 103 CLT Non Conductive
          • 104 Loss of Head
        • Float & Tape
          • 131 T
      • Level Switches
        • Mechanical
          • Side Mounted Float 137 EA
          • Top Mounted Displacer 137 D
          • Side Mounted Pneumatic Control 137 PNP
          • Paddle Type 135 LC
        • Electronic
          • Conductiviy 130 RC
          • Conductiviy 130 IC
          • LIQUIDS 114 MLS
          • Solids 114 MLS
      • Tank Gauging
        • ATLG
          • 133 ATLG Automatic tank level gauge
          • 133 STDT Smart Tank Data Tx
          • 133 TWT
          • 133 LS 2-wire Tx with Limit Switch
        • Servo
          • 139 M series Servo gauge
          • TS/TSIC
          • 133 CIU Communication Interface Unit
          • RCU
          • 133 TMP Average Temperature Sensor
          • PPU
          • Calibration Chamber
        • Magnetostrictive
          • 134 DLi
        • Hydrostatic
          • 103 HPT
          • 171 HTL
    • Flow Measurement
      • Electromangetic Flow Meters
        • 151 MFM P - Process
        • 151 MFM E - Enhanced
        • 151 MFM W - Water
        • 151 MFM B – Battery operated
        • 151 MFM I – Insertion
      • Ultrasonic Flow Meter
        • Parasonic Insertion
          • 153 UTW
        • Parasonic Bulk
          • 153 UIF
        • Parasonic ClampOn
          • 153 UCW
          • 153 UCH
          • 153 UCM
        • Parasonic Multi Path
          • 153-MUF Multipath Ultrasonic Flowmeter
      • Residential Metering
        • AquaSonic 153 RWM
        • AquaLink
      • Open Channel Flow
        • Ultrasonic - 136 ROF
        • Capacitance - 104 ROF
    • Pressure Measurement
      • 171 PT Pressure Transmitter
      • 171 SPT Smart Pressure Transmitter
      • 171 IPT Intelligent Pressure Transmitter
      • 171 DPT Differential Pressure Transmitter
      • 171 BPT Battery Operated Pressure Transmitter
    • IOT
      • 151 MFM – B
      • 138 WB
      • 171 BPT
      • AquaSonic 153 RWM
      • 153 UIF
      • SenSphere Web Application
      • SenSync Mobile Application
    • Accessiores
      • Displays
        • 176 Remote Indicator
        • 176 LPI Loop Power Indicator
        • 103 HTL Tank Level Indicator
        • 191 Totalizer Indicator
      • RTU
        • 200-SB410M
  • Industries
    • Water Treatment Plant
    • Waste Water Management
    • Food and Beverage
    • Power Plants
    • Cement
    • Irrigation
    • Steel
    • Steam Plant
    • Oil and Gas – Upstream
    • Oil and Gas – Downstream
  • Contact Us
  • Home
  • Products
  • Level
  • Level Transmitters
  • Magnetostrictive
  • Active Barrier

Active Barrier

SBEM’s Active Zener Barrier Series 134 ACTZB S is a certified interface solution engineered for seamless power and RS485 communication between non-intrinsically safe (non-IS) and intrinsically safe (IS) circuits in 134 DLi Inventory and Density Probe systems. Designed for global applications in hazardous environments, this Active Zener Barrier complies with ATEX and IECEx standards (60079-0 and 60079-11), ensuring superior safety and performance. The unit features one or two configurable Zener channels, each capable of supporting up to four tanks, with a total capacity of eight probes in a multi-drop configuration. It eliminates the need for earthing and is housed in a non-metallic, IP54-rated enclosure for installation in safe areas. The intrinsically safe outputs can safely extend into EPL Ga zones, making it ideal for global petroleum and chemical industries. Built with fully encapsulated safety-critical components using certified casting compounds, SBEM’s 134 ACTZB S ensures reliable operation in demanding industrial environments.

360° Product View
  • Features
    • ATEX & IECEx Certification – Compliant with international standards.
    • Intrinsically Safe Ex protection Compliance as per 60079-0 & 60079-11
    • Single Barrier protects both Power and RS485 communication line.
    • Available in Single Channel / Dual Channel
    • Supports Multi-Drop Connection
    • Encapsulated Barrier
    • Rugged Enclosure
  • Specification
    Parameter Specification
    Model Series 134 ACTZB S
    Type Active Zener Barrier (Associated Apparatus)
    Certifying Body ATEX / IECEx
    Input Voltage 230VAC
    Communication Protocol RS485 Standard Modbus
    Supported IS Devices 134-DLi Inventory and Density Probes
    Channels 1 or 2 (configurable)
    Probes per Channel Up to 4 (Total 8 per barrier)
    Enclosure Non-metallic, IP54 compliant
    Installation Location Non-hazardous area
    IS Output Connection EPL Ga (Zone 0) compliant
    Certification IECEx / ATEX (IEC/EN 60079-0 & 60079-11)
    Earth Connection Not required
    Mounting Type Stud mounted inside the enclosure
    Encapsulation Certified casting compounds used for all safety-critical parts
  • Application
    • Retail Outlets
    • Petrochemical Facilities:
    • Industrial Facilities with Fuel Backup Systems

    Contact

    • 8600042374 | 7720065260
    • sales@sbem.co.in
    • Gat No. 326, Shriramnagar, Gaud Dara Road, Khedshivapur, Pune - 412205.

    Media

    • News
    • Blogs
    • Gallery

    Careers

    • Life @SBEM
    • Job Opportunities

    We Care

    • Sustainability
    • Safety
    • Social Responsibility

    Support

    • Downloads Leaflets & Brochures
    • Where To Buy
    • FAQs
    © 2025 Copyright SBEM Pvt. Ltd.